T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
No.
T2-05
<1> The setting range and default value shown here is for a 200 V class drive. These values double when using a 400 V class unit.
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No.
T2-06
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note: T2-07 will be displayed when in OLV/PM.
No.
T2-07
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No.
T2-08
T2-09: PM Motor Base Speed
Enter the motor rated speed in min
Note: T2-09 will be displayed when in AOLV/PM and CLV/PM.
No.
T2-09
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No.
T2-10
T2-11: PM Motor d-Axis Inductance
Enter the d axis inductance per motor phase.
No.
T2-11
T2-12: PM Motor q-Axis Inductance
Enter the q axis inductance per motor phase.
No.
T2-12
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Name
PM Motor Rated Voltage
Name
PM Motor Rated Current
Name
PM Motor Base Frequency
Name
Number of PM Motor Poles
-1
.
Name
PM Motor Base Speed
Name
PM Motor Stator Resistance
Name
PM Motor d-Axis Inductance
Name
PM Motor q-Axis Inductance
4.7 Auto-Tuning
Setting Range
0.0 to 255.0 V
<1>
Setting Range
10% to 200% of the drive rated
current.
Setting Range
0.0 to 400.0 Hz
Setting Range
2 to 48
Setting Range
0 to 24000 min
-1
Setting Range
0.000 to 65.000
Setting Range
0.00 to 600.00 mH
Setting Range
0.00 to 600.00 mH
Default
200.0 V
<1>
Default
Depending on o2-04
Default
87.5 Hz
Default
6
Default
1750 min
-1
Default
Depending on T2-02
4
Default
Depending on T2-02
Default
Depending on T2-02