B.3 Parameter Table
b7: Droop Control
No.(Addr.)
Name
b7-01
(1CAH)
Droop Control Gain
b7-02
(1CBH)
Droop Control Delay Time.
b7-03
Droop Control Limit Selection
(17EH)
b8: Energy Saving
No.(Addr.)
Name
b8-01
Energy Saving Control Selection
(1CCH)
b8-02
(1CDH)
Energy Saving Gain
b8-03
(1CEH)
Energy Saving Control Filter Time
Constant
b8-04
Energy Saving Coefficient Value
(1CFH)
b8-05
Power Detection Filter Time
(1D0H)
b8-06
Search Operation Voltage Limit
(1D1H)
b8-16
Energy Saving Parameter (Ki) for
(1F8H)
PM Motors
b8-17
Energy Saving Parameter (Kt) for
(1F9H)
PM Motors
q-Axis Current Compensation
b8-27
Method when Output Voltage is
(B52H)
Limited
<4> Default setting is dependent on the control mode (A1-02), the drive model (o2-04), and the Drive Duty (C6-01).
<8> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning.
<9> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
<10> Default setting is determined by the control mode (A1-02).
<71> The coefficient is 2.00 for software versions S1018 and earlier.
460
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the speed reduction gain applied at a torque reference of 100%. Set as a percentage of
motor base speed.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Used to adjust the responsiveness of Droop Control.
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the gain used for Energy Saving.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets a time constant for Energy Saving.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Determines the level of maximum motor efficiency. Setting range is 0.0 to 2000.0 maximum
output up to 3.7 kW. The display resolution depends on the rated output power of the drive after
the Drive Duty has been set in parameter C6-01. Refer to
Check on page
32.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets a time constant filter for output power detection.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets the limit for the voltage search operation as a percentage of the motor rated voltage.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Coefficient to adjust torque linearity
Set to the Kt value on the motor nameplate.
When E5-01 (Motor Code Selection (for PM Motors)) is set to 1 or 2, the
automatically calculated value will be set. This set value cannot be changed.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Coefficient to adjust torque linearity
Set to the Kt value on the motor nameplate.
When E5-01 (Motor Code Selection (for PM Motors)) is set to 1 or 2, the
automatically calculated value will be set. This set value cannot be changed.
V/f
V/f w/PG
OLV/PM
AOLV/PM
Sets a compensation method for the q-Axis current when output voltage is limited.
There is normally no need to change this parameter from the default value.
0: Output Voltage Limit Priority
1: q-Axis Current Priority
Note: This parameter is not available in models CIMR-A4A0930 and 4A1200.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Model Number and Nameplate
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Setting
Page
Default: 0.0%
Min: 0.0%
179
Max: 100.0%
Default: 0.05 s
Min: 0.03 s
179
Max: 2.00 s
Default: 1
Min: 0
179
Max: 1
Setting
Page
Default:
<10>
Min: 0
179
Max: 1
Default:
<10>
Min: 0.0
179
Max: 10.0
Default:
<4>
Min: 0.00 s
180
Max: 10.00 s
Default:
<8> <9>
Min: 0.00
180
Max: 655.00
Default: 20 ms
Min: 0 ms
180
Max: 2000 ms
Default: 0%
Min: 0%
180
Max: 100%
Default: 1.00
Min: 0.00
180
Max: 3.00
<71>
Default: 1.00
Min: 0.00
181
Max: 3.00
<71>
Default: 0
Min: 0
181
Max: 1