3.8 Main Circuit Wiring
Model
CIMR-A
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0169
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0211
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0250
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0312
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0360
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–, +1
2A0415
+3
<1> When using the wire of this gauge in accordance with IEC/EN 61800-5-1, install an equipment for residual current monitoring/detection
(RCM/RCD).
<2> When using the wire of this gauge in accordance with IEC/EN 61800-5-1, install an equipment for residual current monitoring/detection
(RCM/RCD), or use copper wire of 10 mm
Note: When connecting peripheral devices and options to the terminals –, +1, +3, B1, and B2, refer to the instruction manuals for each
devices. For more information, contact YASKAWA or your nearest sales representative.
78
Recomm. Gauge
Terminal
2
(AWG 8).
Applicable
Gauge
2
mm
mm
70
50 to 95
70
50 to 95
–
35 to 95
–
50 to 95
35
25 to 35
95
70 to 95
95
70 to 95
–
35 to 95
–
50 to 95
50
25 to 50
95 2P
95 to 150
95 2P
95 to 150
–
70 to 150
–
35 to 150
95
95 to 150
95 2P
95 to 150
95 2P
95 to 150
–
70 to 150
–
70 to 150
95
95 to 150
240
95 to 300
240
95 to 300
–
125 to 300
–
70 to 300
120
120 to 240
120 2P
95 to 300
300
95 to 300
–
150 to 300
–
70 to 300
120
120 to 240
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Screw
Size
2
M10
M10
M12
M10
M12
M12
M10
M12
M12
M10
M12
M12
M10
M12
Tightening
Torque
Nm (lb.in.)
18 to 23
(159 to 204)
18 to 23
(159 to 204)
32 to 40
(283 to 354)
18 to 23
(159 to 204)
32 to 40
(283 to 354)
32 to 40
(283 to 354)
18 to 23
(159 to 204)
32 to 40
(283 to 354)
32 to 40
(283 to 354)
18 to 23
(159 to 204)
32 to 40
(283 to 354)
32 to 40
(283 to 354)
18 to 23
(159 to 204)
32 to 40
(283 to 354)