C.9 MEMOBUS/Modbus Data Table
Register No.
Communications Error Contents
bit 0
bit 1
bit 2
003DH
bit 3
bit 4
bit 5
bit 6
bit 7 to bit F
003EH
Output Frequency
003FH
0040H to 004AH
Used for various monitors U1-. Refer to U: Monitors on page 510 for parameter details.
Drive status (U1-12)
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
004BH
bit 6
bit 7
bit 8
bit 9
bit A
bit B
bit E
bit F
Used for various monitors U1-, U4-, U5- and U6-. Refer to U2: Fault Trace on page 512 and U3: Fault History on page 514 for parameter
004CH to 007EH
details.
007FH
Minor Fault Code, Refer to Alarm Register Contents on page 570 for Minor Fault codes.
Used for monitors U2-, U3-. Refer to U: Monitors on page 510 for parameter details and Refer to Fault Trace Contents on page 568 for register value
0080H to 0097H
descriptions.
U4-01 (Cumulative Operation Time)
0098H, 0099H
Example: When U4-01 (Cumulative Operation Time) is 12345 hours, then 0098H = 1234 and 0099H = 5.
U4-03 (Cooling Fan Operation Time)
009AH, 009BH
Example: When U4-03 (Cooling Fan Operation Time) is 12345 hours, then 009AH = 1234 and 009BH = 5.
009CH to 00AAH
Reserved
00ABH
Drive Rated Current
00ACH
Motor Speed (U1-05)
00ADH
00AEH, 00AFH
Reserved
00B0H
Option Code Connected to CN5-A
00B1H
Reserved
00B2H
Option Code Connected to CN5-B
00B3H
Option Code Connected to CN5-C
00B4H
Reserved
00B5H
Frequency Reference After
Soft-starter (U1-16)
00B6H
00B7H
Frequency Reference
00B8H
00B9H to 00BEH
Reserved
00BFH
Lists the last two digits of operation error code oPE.
562
<3>
CRC Error
Data Length Error
Reserved
Parity Error
Overrun Error
Framing Error
Timeout
Reserved
min
-1
<4>
0.01% units
During Run
During Zero Speed
During Reverse Run
During Fault Reset Signal Input
During Speed Agree
Drive Ready
Minor Fault
Fault
During Operation Error (oPE)
During Momentary Power Loss
Motor 2 selected
Reserved
ComRef status, NetRef status
ComCtrl status, NetCtrl status
<2>
min
-1
units
<4>
0.01% units
Register contains ASCII code of the option card.
AI-A3 = 0003H
AO-A3 = 0004H
DI-A3 = 0001H
DO-A3 = 0002H
PG-B3 = 0011H
PG-F3 = 0021H
PG-RT3 = 0023H
PG-X3 = 0012H
SI-C3 = 5343H
SI-EM3 = 1005H
SI-EN3 = 1006H
SI-ET3 = 1004H
SI-N3 = 534EH
SI-P3 = 5350H
SI-S3 = 5353H
SI-T3 = 5354H
SI-W3 = 1003H
min
-1
units
<4>
0.01% units
-1
min
<4>
0.01% units
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual