127-353 LPD Software RAP
Due to a fatal error that occurred in processing related to the LPD, subsequent processes can-
not be performed.
Initial Actions
Power Off/On
Procedure
•
Ask customer to cancel and rerun the job.
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the HDD, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
Status Indicator RAPs
127-353 , 127-354
35.2)
BUS Updated 12/2011
127-354 FTP Server Software RAP
There is a FTP Server software failure.
Initial Actions
Power Off/On
Procedure
Ask customer to cancel and rerun the job.
If the problem persists reload software
07/2011
2-994
(GP
16).
WorkCentre 5335 Family Service Documentation
Initial Issue