500-030 DC612 Print NG By IOT Wait State
The following occurs (However, this includes the cases that may not occur when DC612
starts):
•
Fusing Unit: Shifted to Warming Up and Sagging occurred.
Fusing Unit Relay State: Shifted to Not Ready.
Drum Cycle State: Shifted to Cleaning Request.
Drum Crum State: Unknown.
Procedure
Return from the Wait state and try again.
Initial Issue
WorkCentre 5335 Family Service Documentation
500-033 Diag Document Not Detected/Enough
-When a Diag job requiring a document is performed and the document cannot be detected.
-When a Diag job requiring multiple documents is performed and the number of loaded sheets
is not sufficient to meet the specification.
Procedure
Load the required number of documents and perform the job again.
07/2011
2-1013
BUS Updated 12/2011
Status Indicator RAPs
500-030, 500-033