Strobing (28Mm Or 14Mm Pitch Density); White Streaks (Process Direction) - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

Strobing (28mm or 14mm Pitch Density)

Figure 1 Strobing (28mm or 14mm Pitch Density) Defect Sample
Cause
1.
Developer Magnetic Roll bias.
Corrective Action
1.
Replace the Xerographic
Cartridge(PL
Image Quality
Strobing (28mm or 14mm Pitch Density), White
8.1).
BUS Updated 12/2011

White Streaks (Process Direction)

Figure 1 White Streaks (Process Direction) Defect Sample
Cause
1.
Foreign substances are blocking the ROS Laser.
2.
Developer material clogging on the Developer Magnetic Roll due to foreign substances.
Corrective Action
1.
Clean the light path between the ROS and the Xerographic Cartridge and the seal glass.
2.
Replace the Xerographic Cartridge
07/2011
3-30
(PL
8.1).
Initial Issue
WorkCentre 5335 Family Service Documentation