124-361 CRUM Validation Fail MCU RAP
System Fail. One of CRUM Enable/Disable settings is different from the others (IOT). One of
the CRUM Enable/Disable settings stored in three positions does not match (Data stored in the
MCU Board does not match).
Procedure
•
(Software available for
Machine ID/Billing
•
Enter
Machine ID/Billing
Data. Master SYS1 to resolve the problem. If the problem per-
sists, replace the MCU PWB
(PL
18.2).
(Software unavailable for
Machine ID/Billing
Reload software
GP
16. Replace the MCU PWB
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
Status Indicator RAPs
124-361, 124-362
Data)
Data)
(PL
18.2).
BUS Updated 12/2011
124-362 CRUM Validation Fail SYS 1 RAP
System Fail. One of CRUM Enable/Disable settings is different from the others (SYS 1). One of
the CRUM Enable/Disable settings stored in three positions does not match (Data stored in the
ESS PWB
(PL
35.2) does not match).
Procedure
•
(Software available for
Machine ID/Billing
Enter
Machine ID/Billing
Data. Master the MCU to resolve the problem. If the problem per-
sists, replace the Cont PWB.
(Software unavailable for
Machine ID/Billing
Reload software
GP
16. Remove the EEPROM from and reinstall it into the ESS PWB
(PL
35.2).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
07/2011
2-978
Data)
Data)
Initial Issue
WorkCentre 5335 Family Service Documentation