123-333 Interface Communication RAP
BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
The system detected that transmission with the Control Panel could not be established.
The H/W connection in the UI is faulty and the internal connection isn't detected.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace UI I/F PWB
(PL
1.7)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
Initial Issue
WorkCentre 5335 Family Service Documentation
123-337 Frame Data RAP
BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
The UI software failed and an incorrect data type value is detected.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace UI I/F PWB
•
Replace ESS PWB
07/2011
2-933
BUS Updated 12/2011
(PL
1.7)
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)