REP 12.22 Eject Belt
Parts List on
PL 22.9
Removal
1.
Switch off the power and disconnect the power cord.
2.
Remove the Integrated Office Finisher from the machine
3.
Remove the Compiler Assembly
(REP
4.
Remove the Front/Rear Tamper Motor Assembly
5.
Move the Eject Home Sensor Assembly
(1)Remove Screw.
(2)Move Eject Home Sensor Assembly.
Figure 1 Moving the Eject Home Sensor Assembly (j0fa42279)
6.
Remove the Eject Belt
(Figure
2):
(1)Move the blades of Set Clamp Shaft in the direction of the arrow.
(2)Remove Eject Belt in the direction of the arrow.
Repairs & Adjustments
REP 12.22
(PL
22.1).
12.20)
(REP
12.26)
(Figure
1):
BUS Updated 12/2011
Figure 2 Removing the Eject Belt
Replacement
1.
Reverse the removal procedure for replacement.
2.
Install and align the Eject Belt with marks on the Pulleys
Figure 3 Eject Belt Alignment