078-250 Hcf Lift Fault Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

078-250 HCF Lift Fault RAP

BSD-ON:
BSD 7.10 - HCF (Tray 6) Paper Stacking
HCF Tray Lift failure. The Tray 6 Level Sensor does not turn ON within the specified time after
the trays were inserted.
Initial Actions
Clear any jam and switch the power off then on.
Check the size of the paper in the tray.
Remove any debris or foreign substances in the tray.
Procedure
Open and close Tray 6. The Tray 6 Lift/Feed Motor operates
Y
N
Check the circuit between
PF/JF58
HCF PWB for an open or a short circuit, or a loose or damaged connector. The
are OK.
Y
N
Repair as required.
Check that the resistance through Tray 6 Lift/Feed Motor is approx. 0.8 ohms at the mea-
surement points below.
PF/JF58-3 to pins 1/2
PF/JF58-4 to pins 5/6
The resistances are OK+
Y
N
Replace the Tray 6 Lift/Feed Motor
There is +24VDC from PF/JF pins 3 and 4, to GND.
Y
N
Go to
IOT wirenets
and troubleshoot the +24VDC circuit.
Replace the Tray 6 Lift/Feed Motor
PWB
(PL
10.8).
Check the installation of the Tray 6 Stack Height Sensor
actuator. The Stack Height Sensor is installed correctly and the actuator works.
Y
N
Reinstall the Tray 6 Stack Height Sensor.
Execute
Component Control
[078-201], Tray 6 Stack Height Sensor. Manually activate the Tray
6 Stack Height Sensor. The display changes.
Y
N
Check the wires between
PF/JF62
on the Tray 6 Stack Height Sensor and PF/JF 102 on
the HCF PWB for an open or shorted circuit, or a loose or damaged connector. The
wires are OK.
Y
N
Repair as required.
A
B
Initial Issue
WorkCentre 5335 Family Service Documentation
on the Tray 6 Lift/Feed Motor and PF/JF 06 on the
(PL
10.4).
(PL
10.4). If the problem persists, replace the HCF
(PL
10.5) and the operation of the
BUS Updated 12/2011
A
B
There is approx. +5VDC from PF/JF 02 pin 3 to GND.
Y
N
Replace the HCF PWB
Monitor the voltage between PF/JF62-2 (+) and GND (-) while you activate the actuator
of the Tray 6 Stack Height Sensor. The voltage changes.
Y
N
Replace the Tray 6 Stack Height Sensor
Replace the following the HCF PWB
Check the mechanical components
broken or out-of-place cables. If OK, replace the HCF PWB
wires
07/2011
2-819
(PL
10.8).
(PL
10.5).
(PL
10.8)
(PL
10.4) of the lift mechanism for dirty or damaged gears,
(PL
10.8).