078-250 HCF Lift Fault RAP
BSD-ON:
BSD 7.10 - HCF (Tray 6) Paper Stacking
HCF Tray Lift failure. The Tray 6 Level Sensor does not turn ON within the specified time after
the trays were inserted.
Initial Actions
•
Clear any jam and switch the power off then on.
•
Check the size of the paper in the tray.
•
Remove any debris or foreign substances in the tray.
Procedure
Open and close Tray 6. The Tray 6 Lift/Feed Motor operates
Y
N
Check the circuit between
PF/JF58
HCF PWB for an open or a short circuit, or a loose or damaged connector. The
are OK.
Y
N
Repair as required.
Check that the resistance through Tray 6 Lift/Feed Motor is approx. 0.8 ohms at the mea-
surement points below.
•
PF/JF58-3 to pins 1/2
•
PF/JF58-4 to pins 5/6
The resistances are OK+
Y
N
Replace the Tray 6 Lift/Feed Motor
There is +24VDC from PF/JF pins 3 and 4, to GND.
Y
N
Go to
IOT wirenets
and troubleshoot the +24VDC circuit.
Replace the Tray 6 Lift/Feed Motor
PWB
(PL
10.8).
Check the installation of the Tray 6 Stack Height Sensor
actuator. The Stack Height Sensor is installed correctly and the actuator works.
Y
N
Reinstall the Tray 6 Stack Height Sensor.
Execute
Component Control
[078-201], Tray 6 Stack Height Sensor. Manually activate the Tray
6 Stack Height Sensor. The display changes.
Y
N
Check the wires between
PF/JF62
on the Tray 6 Stack Height Sensor and PF/JF 102 on
the HCF PWB for an open or shorted circuit, or a loose or damaged connector. The
wires are OK.
Y
N
Repair as required.
A
B
Initial Issue
WorkCentre 5335 Family Service Documentation
on the Tray 6 Lift/Feed Motor and PF/JF 06 on the
(PL
10.4).
(PL
10.4). If the problem persists, replace the HCF
(PL
10.5) and the operation of the
BUS Updated 12/2011
A
B
There is approx. +5VDC from PF/JF 02 pin 3 to GND.
Y
N
Replace the HCF PWB
Monitor the voltage between PF/JF62-2 (+) and GND (-) while you activate the actuator
of the Tray 6 Stack Height Sensor. The voltage changes.
Y
N
Replace the Tray 6 Stack Height Sensor
Replace the following the HCF PWB
Check the mechanical components
broken or out-of-place cables. If OK, replace the HCF PWB
wires
07/2011
2-819
(PL
10.8).
(PL
10.5).
(PL
10.8)
(PL
10.4) of the lift mechanism for dirty or damaged gears,
(PL
10.8).
Status Indicator RAPs
078-250