033-324 Usb State Change Error Rap; 033-325 Fax Pwb Fatal Error Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

033-324 USB State Change Error RAP

BSD-ON:
BSD 34.1 - FAX
USB entered into an unexpected state.
Procedure
Switch the power off, then on.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the PWB's in the FAX Module
Check the sw version of the fax & controller sw - update if required
Perform FAX Diagnostic
GP 13
Replace the Fax PWB
(PL
18.5)
Status Indicator RAPs
033-324, 033-325

033-325 Fax PWB Fatal Error RAP

BSD-ON:
BSD 34.1 - FAX
Bit error found during debugging of Fax PWB
Procedure
Switch the power off, then on.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the PWB's in the FAX Module
Check the sw version of the fax & controller sw - update if required
Perform FAX Diagnostic
Replace the Fax PWB
07/2011
2-514
BUS Updated 12/2011
GP 13
(PL
18.5)
WorkCentre 5335 Family Service Documentation
Initial Issue

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents