047-216 Finisher Communication Fail RAP
BSD-ON:
BSD 3.6 - IOT-Finisher Communication
Communication failure between the Finisher and the IOT was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check the connection between the MCU PWB
Finisher PWB
P/J8704
(Integrated) or
poor contact. Also, check the power supply at the Finisher.
If no problems are found, replace the MCU PWB
Status Indicator RAPs
047-216, 047-217
P/J422
J8889
(External) for open circuit, short circuit, and
(PL
18.2).
BUS Updated 12/2011
047-217 HCF Communication Fault
BSD-ON:
BSD 3.10 - MCU-HCF Communications
Communication failure between the HCF and the IOT was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
and the
2.
Turn the power OFF and check the connection between the MCU PWB
HCF PWB J 800A and J 800B for open circuit, short circuit, and poor contact. Also, check
the power supply at the HCF.
If no problems are found, replace the HCF PWB
PWB
(PL
18.2).
07/2011
2-768
P/J419
(PL
10.8) before replacing the MCU
Initial Issue
WorkCentre 5335 Family Service Documentation