116-338 JBA RAP
A JBA (Job Based Accounting) processing error caused an internal shutdown.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs
116-338, 116-339
35.2)
BUS Updated 12/2011
116-339 JBA No HD RAP
When the JBA is started up, the HDD is not installed.
Procedure
•
Check the HDD electrical connections
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
07/2011
2-860
(PL
35.2).
Hard Disk Failure Prediction
Test.
WorkCentre 5335 Family Service Documentation
Initial Issue