033-517 ECM Phase C Flag Timeout RAP
BSD-ON:
BSD 34.1 - FAX
ECM Phase C Flag Timeout
Procedure
•
Check the status of the machine sending the fax, and retry fax job.
•
Check phone line connection, grounding, electrical noise
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB's in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the FAX PWB
(PL
18.5)
Status Indicator RAPs
033-517, 033-518
033-518 Remote Cannot Receive SUB RAP
BSD-ON:
BSD 34.1 - FAX
Receiving machine does not support SUB
Procedure
•
Check the status of the machine sending the fax, and retry fax job.
•
Check phone line connection, grounding, electrical noise
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB's in the FAX Module
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
•
Replace the FAX PWB
07/2011
2-530
BUS Updated 12/2011
GP 13
(PL
18.5)
WorkCentre 5335 Family Service Documentation
Initial Issue