ADJ 12.1 Finisher LX Hole Punch Position
Purpose
This procedure sets the distance from the trail edge of the punched sheet to the center of the
punched holes.
NOTE: This adjustment is normally performed by the customer, via Admin mode.
Check
1.
Enter the Service Rep. Mode
(Accessing UI
ment (on second page).
2.
Select Adjust Punch Position/Booklet Fold Position.
3.
Select choice #1 or #2, depending on the paper size, then select Change Settings.
4.
Select Sample Printout.
5.
Select the paper tray to be adjusted, then press Start. The selection must match the
choice made above.
6.
Measure the distance between the trail edge of the sheet and the center of the bottom
hole. If the distance is not 10 +/- 3 mm, perform the Adjustment
Adjustment
1.
Use the buttons on the UI to move the holes left or right. When the computed correction is
made, select Adjust.
2.
Repeat the Check and Adjustment until the measurement is correct
Initial Issue
WorkCentre 5335 Family Service Documentation
Diagnostics) and select Finisher Adjust-
07/2011
BUS Updated 12/2011

ADJ 12.2 Finisher LX Booklet Crease/Staple Position

Purpose
This procedure centers the crease and staple positions in the booklet.
NOTE: This adjustment is normally performed by the customer, via Admin mode.
Check
1.
Enter the Service Rep. Mode
ment (on second page).
2.
Select Adjust Punch Position/Booklet Fold Position.
3.
Select choice #3 or #4, depending on the paper size, then select Change Settings.
4.
Select Sample Printout.
5.
Select a paper tray with the appropriate paper, then press Start. The selection must
match the choice made above.
6.
Measure the distance between the crease and the edges of the sheet ("A" and "B" on
ure
1). The measurements should be equal, +/- 3.5 mm for A4/Letter size paper; 4 mm for
all other sizes.
Figure 1 Measurements
7.
Measure the distance between the crease and the staples ("X1" on
surements should be less than 2.5 mm.
8.
If either measurement is not within spec, perform the Adjustment.
Adjustment
1.
Examine the printed sample and determine which of 4 choices best describes the mis-
alignment; select the button for that description.
NOTE: The graphic in the following step is not displayed until a misalignment choice is made.
2.
Measure "A" and "B" per the graphic displayed on the UI. Enter the correction and select
Adjust.
3.
Repeat the Check and Adjustment until the measurement is correct.