123-318 Receive Finish Queue RAP
BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
The data received from the Controller exceeded the upper limit of the processing capability in
the UI.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace UI I/F PWB
(PL
1.7)
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
Status Indicator RAPs
123-318, 123-320

123-320 NVM Initialized for FCW Composition RAP

BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
Automatic recovery with detection of incorrect value in system data area that is not compatible
between different UI panels (FCW/HB).
When the M/C was started or booted, it was detected that a value, which is out of the
guaranteed range for the currently installed panel, is set in the system data area that has
no compatibility among the different type of UI panels (HB/FCW/MCW).
This error does not occur during the usual physical UI panel type replacement.
If for some reason the incorrect data got stored, the machine performs reboot and auto-
matic recovery using the same system as when the panel is physically replaced.
Initial Actions
Power Off/On
Procedure
Even when this error code is displayed, the machine can still be used normally after
pressing [Close].
However, set necessary settings before using it because the Controller NVM has been ini-
tialized into the FCW/MCW panel configuration.
Disconnect and reconnect the electrical connections on the UI PWB and the ESS PWB.
If the problem persists reload software
If the problem persists replace the Control Panel Assembly