078-100Tray 6 (HCF) Pre Misfeed RAP

BSD-ON:
BSD 7.10 - HCF (Tray 6) Paper Stacking
BSD-ON:
BSD 8.6 - HCF (Tray 6) Paper Feeding
Tray2 Pre Feed Sensor is not turned ON by the paper in specified time from Tray 2 Feed Start.
Initial Actions
A paper transportation failure due to a foreign substance/burr on the paper path
The Tray 6 Feed Roll, Retard Roll, and Nudger Roll for contamination, wear, and revolu-
tion failure (when the jam has occurred during Feed from Tray 6)
Use of paper out of spec
The Tray 6 Pre Feed Sensor for contamination, improper installation, and Actuator opera-
tion failure
Procedure
Execute
Component Control
[078-100], Tray 6 Pre Feed. Sensor. Block and unblock the Sen-
sor. The display changes.
Y
N
The connection between the Tray 6 Pre Feed. Sensor
JF02
for open circuit, short circuit, and poor contact. If OK, replace the Tray 6 Pre Feed.
Sensor
(PL
10.5)
Open and close Tray 6. The Tray 6 Lift/Feed Motor operates
Y
N
Check the circuit between
PF/JF58
HCF PWB for an open or a short circuit, or a loose or damaged connector. The
are OK.
Y
N
Repair as required.
Check that the resistance through Tray 6 Lift/Feed Motor is approx. 0.8 ohms at the mea-
surement points below.
PF/JF58-3 to pins 1/2
PF/JF58-4 to pins 5/6
The resistances are OK+
Y
N
Replace the Tray 6 Lift/Feed Motor
There is +24VDC from
PF/JF06
pins 3 and 4, to GND.
Y
N
Go to
IOT wirenets
and troubleshoot the +24VDC circuit.
Replace the Tray 6 Lift/Feed Motor
PWB
(PL
10.8).
Check the following:
The Tray 6 Pre Feed Sensor for failure:
The Tray 6 Feed/Lift Motor failure:
Component Control
Initial Issue
WorkCentre 5335 Family Service Documentation
PF/JF61
and the HCF PWB
on the Tray 6 Lift/Feed Motor and
PF/JF06
(PL
10.4).
(PL
10.4). If the problem persists, replace the HCF
Component Control
[078-100]
(PL
10.5)
[078-003] CW
(PL
10.4)
BUS Updated 12/2011
The Tray 6 In Sensor failure:
The connection between the Tray 2 Pre Feed Sensor PF61 and the HCF PWB PF02 for
open circuit, short circuit, and poor contact
Reload the machine software
18.2).
PF/
on the
wires
07/2011
2-815
Component Control
[078-204] CW
(PL
(GP
16). If no problems are found, replace the MCU PWB