Exit 2 Cooling Fan Removal - Lexmark X850e Service Manual

Hide thumbs Also See for X850e:
Table of Contents

Advertisement

Exit 2 cooling fan removal

1.
Remove the exit 2 unit assembly. See
2.
Open the exit 2 unit assembly.
3.
Remove the exit 2 left cover. See
4.
Remove the exit 2 right cover. See
5.
Disconnect the connector from the exit 2 cooling fan (A).
6.
Remove the harness from the hole in the exit 2 unit assembly.
7.
Remove the screw securing the exit 2 cooling fan (A) to the exit 2 unit assembly.
8.
Remove the exit 2 cooling fan (A).
Rear
"Exit 2 unit assembly removal" on page
"Exit 2 left cover removal" on page
"Exit 2 right cover removal" on page
Hole
4-315.
4-319.
4-320.
Connector
A
Marker
Cover
Clamp
Clamp
A
Repair information
7500-XXX
4-331