7500-XXX

MPF pressure pad removal

1.
Remove the MPF rear cover. See
2.
Remove the MPF feed unit assembly. See
3.
Remove the MPF pick roll. See
4.
Remove the MPF feed shaft assembly. See
5.
Remove the two springs (A) under the pressure pad (B).
6.
Turn the MPF upside down, and pry the shaft out with a flat blade screwdriver.
7.
Remove the separation pad (B) and the shaft (C) by moving it in the direction of the arrow from the
backside.
Note: Before reinstalling, ensure the two springs (A) remain in the proper position during reassembly of the
feed shaft assembly and MPF feed roll.
4-60
MFP Service Manual
"MPF rear cover removal" on page
"MPF feed unit assembly removal" on page
"MPF pick roll removal" on page
"MPF feed shaft assembly removal" on page
B
C
A
Rear
Botton
Front
4-58.
4-64.
A
C
4-54.
4-63.