AC power input socket removal

1.
Remove the rear RIP card cover. See
2.
Remove the rear motor cover. See
3.
Remove the rear lower cover. See
4.
Remove the three screws securing the bracket (A).
5.
Disconnect the two connectors to the AC power input socket (B).
6.
Remove the two screws securing the AC power input socket (B) to the bracket (A).
7.
Remove the AC GFI breaker (B).
Warning: Before reinstalling, ensure all connectors are plugged into their proper location to prevent
damage.