7500-XXX

Standard bin full exit 2 actuator removal

1.
Remove the exit 2 unit assembly. See
2.
Open the exit 2 unit assembly (A).
3.
Remove the exit 2 left cover. See
4.
Remove the exit 2 right cover. See
5.
Remove the standard bin full exit 2 actuator outer (A) from the spring (B).
6.
Release the hooks securing the standard bin full exit 2 actuator inner (C) to the right cover (D).
7.
Release the spring (B) from the hook of the standard bin full exit 2 actuator inner (C).