MPF transport roll assembly removal

1.
Remove the MPF rear cover. See
2.
Remove the MPF feed unit assembly. See
3.
Remove the two end screws securing the upper bracket to the MPF feed unit assembly.
4.
Remove the upper bracket.
5.
Remove the MPF transport gear - 18 tooth (A).
Note: The MPF transport gear - 18 tooth will be tight and requires extra force to remove.
6.
Remove the transport shaft collar (B).
7.
Remove the e-clip with a prying tool securing the MPF transport roll assembly (C) to the MPF feed unit
assembly.
8.
Remove the two bushings 8 mm (D).
9.
Remove the MPF transport roll assembly by moving it rightward then upward in the direction of the arrow.
Note: When removing the MPF transport roll assembly (C), do not touch the rubber surface.
E-clip
D
Note: Before reinstalling the MPF transport roll assembly (C), do not touch the rubber surface.
"MPF rear cover removal" on page
"MPF feed unit assembly removal" on page
Right
4-58.
4-54.
C
D
B
A
Repair information
7500-XXX
4-61