Quick Test - Lexmark X850e Service Manual

Hide thumbs Also See for X850e:
Table of Contents

Advertisement

Perform a Quick Test. See
Margin Setting
2
Top Margin
3
Tray 1 Left Margin
Tray 2 Left Margin
Tray 3 Left Margin
Tray 4 Left Margin
Tray 5 Left Margin

Quick Test

1
Each increment of adjustment corresponds to:
1 scan at 300 dpi for the Top Margin setting or
1 pel at 300 dpi for each Left Margin setting
2
Increasing the registration value moves text up the page and widens the top margin; decreasing the registration
value moves text down the page and narrows the top margin. The entire image moves up or down the page;
therefore, no compression or expansion of the image occurs to preserve the bottom margin.
3
Increasing the registration value moves the margin to the left; decreasing the registration value moves the
margin to the right. The entire image moves left or right on the page; therefore, no compression or expansion of
the image occurs to preserve the right margin.
To change the value of any of the margin settings:
1.
Touch
to the right of the appropriate margin setting. The panel displays the setting's name in the
header and
[setting's current value]
2.
Touch
to decrease the value and
3.
Touch Back to cancel and return to the Configuration Menu.
4.
Touch Submit to save the change, at this time an alignment page will print.
The device prints a Quick Test page from the appropriate paper tray. While the Quick Test page prints,
Printing Alignment Page appears on the LCD.
Quick Test
The Quick Test verifies that the Registration margin values of the device's default input source are set
appropriately.
To print the Quick Test page:
1.
Touch REGISTRATION from the Configuration Menu.
2.
Touch Quick Test.
3.
Touch Back to return to REGISTRATION.
4.
Touch Back again to return to the Configuration Menu.
The printed Quick Test page consists of:
Alignment diamonds
Horizontal lines used for skew adjustment
General printer information to include current page count and installed memory
The printer's serial number, code levels, and print registration settings
"Quick Test" on page
3-10.
1
Range
0..50
-50..50
-50..50
-50..50
-50..50
-50..50
This cannot be adjusted, but is an option in the Registration
Menu. It also happens when one of the Margins above is
adjusted.
in a menu below the header row.
to increase the value.
7500-XXX
Units
1/300 inch
1/300 inch
1/300 inch
1/300 inch
1/300 inch
1/300 inch
3-37
Diagnostic aids

Advertisement

Table of Contents
loading

This manual is also suitable for:

X852eX854e

Table of Contents