Exposure lamp PS card assembly removal
1.
Remove the large platen glass. See
2.
Remove the screw securing the exposure lamp PS card assembly (A) to the scanner carriage (B).
3.
Move the exposure lamp PS card assembly rearward then release the two hooks securing it to the scanner
carriage (B).
4.
Remove the exposure lamp PS card assembly (A).
5.
Disconnect the exposure lamp (C) from the exposure lamp PS card assembly (A).
6.
Disconnect the exposure lamp PS ribbon cable (D) from the exposure lamp PS card assembly (A).
7.
Remove the two screws securing the exposure lamp PS card assembly to the insulator bracket (E).
8.
Remove the insulator bracket (E).
Note: Before reinstalling the exposure lamp PS card assembly (A), ensure that all connections are properly
connected.
Note: Ensure that all harnesses and cables move freely without binding.
Note: Ensure that the exposure lamp PS card assembly is securely mounted to the scanner carriage (B).
C
"Large platen glass removal" on page
B
4-142.
E
D
A
Repair information
7500-XXX
4-157