System; Hard Wired; Zones 5&6 (Basic Control's Zones); Configurations - ADEMCO Via 30+ Installation Instructions Manual

Hide thumbs Also See for Via 30+:
Table of Contents

Advertisement

Section
2.
SYSTEM
CONFIGURATIONS
HARD-WIRED
ZONES
Zones 5&6
The Ademco
via30+ supports 2 hard-wired zones, which are connected as
1
zones 5 & 6 (zones 1 ~ 4 are not present in this system). These zones must be
Garie :Coniols zones
EOLR supervised, and can use N.O. and/or N.C. sensors.
Zone
Response
Type | Any zone response can be assigned to devices on
these zones except Supervised Fire (09), which
can be assigned only to zone 5 (see below).
Response
Time
300—500 msec.
Max.
Zone
Resistance | 300 ohms, excluding EOLR
EOLR
Supervised
* Supports both open circuit and closed circuit
devices.
¢ Connect open circuit devices in parallel across
the
loop. The
1,000
ohm
EOLR
must
be
connected across the loop wires at the last
device.
Important: lf the EOLR is not at the end of the
loop, the zone is not properly supervised. The
system may not respond to an open circuit within
the zone.
Connect closed circuit devices in series with the
HI side of the loop.
Of the 2 hard-wired zones, only zone 5 can be
used for fire.
Supports as many 4-wire smoke detectors as can
be powered.
The
zone
must
be
configured
for EOLR
supervision.
The detectors must be wired in parallel, with the
EOLR at the last detector for full supervision.
To supervise power, a supervisory module (e.g.,
System
Sensor
No. A77-716B
EOL
Relay
Module) is required.
EOLR
Fire Zone
5