Removing A Gpgpu Card; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Server
Table of Contents

Advertisement

9.4.2

Removing a GPGPU card

Upgrade and Repair Units (URU)
Average task duration: 10 minutes
9.4.2.1

Required tools

Preliminary and concluding steps: tool-less
Removing a GPGPU card
– Phillips PH2 / (+) No. 2 screw driver
9.4.2.2

Preliminary steps

Before removing an expansion card, perform the following steps:
Ê Disable BitLocker functionality as described in section
functionality" on page
Ê Shut down the server as described in section
page
69.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section
from the mains" on page
Ê Remove all external cables from the expansion card to be removed.
Ê When working on a rack-mounted server, extend it out of the rack as
described in section
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
Ê Bring the server to its horizontal position.
Ê Open the side / top cover as described in section
on page 77
(rack server) or
server).
Ê Remove the air duct as described in section
on page
98.
TX300 S7 / RX350 S7
139.
70.
"Extending the server out of the rack" on page
"Removing the side cover" on page 86
Upgrade and Maintenance Manual
Expansion cards and backup units
"Disabling BitLocker
"Shutting down the server" on
"Disconnecting the server
75.
"Removing the top cover"
"Removing the system air duct"
74.
(tower
469