Accessible drives
Figure 427: Installing the 3.5-inch installation frame in the Multibay box (B)
Ê Secure the installation frame in the Multibay box with two screws (M3 x 6
mm) on either side.
Ê Before inserting the Multibay box into the chassis, connect the LSD cable to
the LSD module:
Cabling
1
list no.
14
1
The cabling list numbers refers to section

12.5.1.5 Removing accessible drive dummy covers

Removing accessible drive filler covers
Ê Remove the accessible drive filler cover from installation bay 1 as described
in section
"Removing accessible drive filler covers" on page
V
CAUTION!
Always replace filler covers into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Removing accessible drive covers
Ê Remove the accessible drive cover from installation bay 1 as described in
section
"Removing accessible drive covers" on page
646
Cable
LSD cable
(T26139-Y3718-V301)
Upgrade and Maintenance Manual
"List of used cables" on page
611.
861.
610.
TX300 S7 / RX350 S7