Required Tools; Preliminary Steps; Removing An Fbu Module From The Chassis - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Server
Table of Contents

Advertisement

Expansion cards and backup units
9.6.7.1

Required tools

Preliminary and concluding steps: tool-less
Replacing an FBU: tool-less
9.6.7.2

Preliminary steps

Before replacing an FBU, perform the following steps:
Ê Disable boot watchdog functionality as described in section
SVOM boot watchdog functionality" on page
Ê Locate the defective server as described in section
server" on page
Ê Shut down the defective server as described in section
server" on page
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section
from the mains" on page
Ê When working on a rack-mounted server, extend it out of the rack as
described in section
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
Ê Open the side / top cover as described in section
on page 77
(rack server) or
server).
Ê Remove the air duct as described in section
on page
98.
Ê Remove the system fan holder as described in section
system fan holder" on page
9.6.7.3

Removing an FBU module from the chassis

Ê Remove the FBU module from the chassis as described in section
"Removing an FBU" on page
524
62.
69.
70.
"Extending the server out of the rack" on page
"Removing the side cover" on page 86
386.
515.
Upgrade and Maintenance Manual
"Disabling
140.
"Locating the defective
"Shutting down the
"Disconnecting the server
75.
"Removing the top cover"
"Removing the system air duct"
"Removing the
TX300 S7 / RX350 S7