LCD Messages
Dump:
While in the Dump
mode,
enter MSG, three characters,
then press Enter.
The
characters
represent
stored
messages
for either an
individual
station
port (000 - 239), ALL (all stations
and system data) or S Y S (system data only). For a
printout example, see Figure 13-7.
>MODE DUMP
D MSG SYS
SYS
M60
OUT TO LUNCH
SYS
M61
IN A MEETING
SYS
M62
CALL
SYS
M63
BACK AT
SYS
M64
RETURN ON
SYS
M65
SYS
M66
SYS
M67
SYS
M68
SYS
M69
D
Figure 13-7
n
Establish
a talk path between
the two remote
Sample Printout of System Messages
stations
(B & C) via a CO-to-CO
connection
through Strata DK.
Tl Error
Dump:
While in the Dump
mode,
enter
TlERR;
press Enter.
A Tl
error status
will then
appear on the terminal or PC screen.
Data dump tables later in this chapter provide a quick
reference to the step-by-step
procedures
to output the
appropriate
data.
Trace Dump:
While in the Dump mode, enter TRC,
then Enter.
DK280 data activity will be sent to the
terminal or PC. Trace data is intended to be used for
troubleshooting
by trained
engineers,
only. To stop
Trace,press
Delete
and Enter.
January
1996
13-13
13.10
Test Mode
The remote
test mode
can be used to test Strata
DK280 stations
and CO line circuits from an off-site
location.
This testing
function
is accomplished
by accessing
stations
from the remote
terminal,
and activating
various buttons on digital and electronic telephones
to
make telephone
calls, set function buttons, change the
system time and date, etc. (see Figure 13-8).
IMPORTANT!
Any digital or electronic
telephone
button can
be activated
from the remote terminal at any
time while in the Test Mode (even while the
end user is using the telephone).
Therefore,
caution
must
be used
to prevent
service
interruption
or interference.
The Test Mode
provides
status tests to check whether or not
a station
or CO line is in use. The status
checks
should
always
be made
before
performing
other tests.
13.10.1
CO line
Testing
To test CO line transmission,
two or three CO lines
must be available at the remote site (see Figure 13-8).
CO line testing
is accomplished
by using all of the
following three methods:
W
Call station
B at the remote
site via the Strata
DK280
system
and then place the line on hold
(transmission
is checked
at the remote
site via
Music-on-Hold).
n
Establish a talk path between a remote station and
the time
or weather
service
via a CO-to-CC
connection
through Strata DK.
The procedures
in the tables provide examples
of the
types of tests and functions that can be accomplished
with the Test Mode. These procedures
do not cover all
the possible
tests that can be performed
remotely;
however,
by using the principles given, other tests are
possible.
13.11
LCD Message Mode
This mode allows
a local or remote
terminal
to set
Called and Calling Station LCD messages
for station
users. The messages
may be system or station type
and are stored in their respective
memory
locations
when set.

Hide quick links: