Minimum
Software
Requirements
To prepare
the system
software
for programming,
clear the memory by initializing its data (with Program
91-g),
as specified
in Section
8.4-General
Programming
Guidelines.
Next, after installing
all of
the PCBs, Program 91-1 or 91-9 must be run to inform
the software
of the system's hardware
configuration.
After running Program 91-l or 91-9, run Program .03
for all PCBs
that
have
options.
Basic
system
programming
can then begin.
8.4
General Programming
Guidelines
The following is a general procedure
for programming
the system.
1.
Run Program 91-9 twice in succession to initialize
the system. All PCBs may or may not be installed
- it does not matter.
CAUTION
!
Program 91-9 will erase all program
data and
will drop a// calls if it is run while the system is
in service.
Program 91-9 sets the following elements to initial
status:
+
Data for Programs 00 - *99
+
Speed Dial Memory
+
Voice Mail Identification
Codes
+
Character Message Memory
+
Timed Reminders
+
Digital Telephone
Volume Levels
+
Call Forward Memory (Power OFF, then ON).
2.
After installing
all PCBs, run Program
91-1 to
inform
the software
of the system
hardware
configuration.
8.4.1
After Initialization
Immediately
after initializing the system with Program
91-9 and 91-1:
1.
Run Programs 03 and 19-1 to inform the software
of the system option hardware
configuration
(see
Table 8-7, and the Program 19 record sheet)
2.
Run Program 00 to assign remote
maintenance
security codes (see Table 8-8). With Strata DK280
Release 3 and above, anytime after initialization,
the RCTU processor
PCB RAM can be tested
using Program 00. The RCTU RAM test procedure
is provided on the Program 00-Part 2 record sheet
in Chapter 10 -Record
Sheets.
3.
Run additional programs as required.
.
All programs
are entered
from the LCD digital
or
electronic
telephone
connected
to physical Port
005
or, they are uploaded
using 280Admin
or 280Backup.
If uploading
with 280Admin
or 280Backup,
you must
download
Program 03 first to set the correct PCB slot
code data in the 280Admin
or 280Backup
database.
The
time
and
date
can
be set
anytime
after
initialization.
This is not accomplished
from the
programming
station,
but rather from the digital or
electronic
telephone
connected
to logical Port 000
(usually station number 200).
Refer to Figures 8-3 for the date, 8-4 for the system
time,
and 8-5 for the day. of the week
(Monday,
Tuesday,
etc.). Program 91-9 does not initialize time
and date.
January
1996
8-5

Hide quick links: