Toshiba Strata DK 280 Installation Manual page 177

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Ribbon
Cable
DK280
BASE
CABINET
with
RCTUCB!
D3 or RCTUBAB
I RCTUBBB
Ribbon Cable
Install ribbon
cables as shown
Install ribbon
cables as shown
P-connector
Ribbon
Cable
(supplied
with RCTU)
&connector
Ribbon
Cable
Figure
4-39
RSIU PCB Installation
SLOT
t RCTUCB
b7SlU
IPDKU
DK280
BASE
CABINET
with
RCTUAB
-
SLOT
RCTUAB
b=s.lU
PDKU
PCB
TYPE
kKU
1.
Identify (mark) the attendant
console
and all
station PCB wiring connectors
so they can be
removed
and then
reinstalled
on the same
PCB later (Console
Station
PCBs include:
PDKU, RDSU,
PEKU, PEW,
RSTU,
PSTU
and RATU PCBs).
2.
Turn system power off.
3.
Disconnect
the connectors
from the Attendant
Console and all Station PCBs listed in Step 1.
4.
Remove all Station PCBs listed in Step 1.
5.
install each PCB that was removed
in Step 4
into the next highest empty station
PCB slot
number. Skip over all other types of PCBs that
were not removed.
Example:
If a PDKU was
originally in slot 11 and a PSTU was in slot 12,
the PDKU is moved to slot 12 and the PSTU
is moved
to slot
13. The
programming
telephone
will then be on the 6th circuit (port
005; or, 013 until Program 03 Code 49 is set
for slot 11) of the PDKU in slot 12.
6.
Connect
all PCB connectors
that
were
removed
back into the same PCBs they were
removed from in Step 3.
7.
Turn the system
power on and note that the
programming
telephone
is on port 13 and all
other
ports
are shifted
up by eight
ports.
Program
slot 11 with Code 49 and all other
slots
with
the
appropriate
codes
using
Program
91-1 and/or 03. Then cycle system
power
off (five
seconds)
and on, or, run
Program
91-2 to transfer
Program
03 data
from temporary
to working
memory.
At this
time the programming
telephone
changes
from port 13 to port 005 and all other ports
shift down by eight ports.
n
RSIU installed
into an existing
system
with DID
and/or tie lines:
All information
provided
in the first paragraph
regarding
RSIU installation
into a new system
applies
to installing
an RSIU
into an existing
system. Hence, most PCBs must be moved to the
next highest slot using the following steps.
1.
Identify
(mark) all PCB wiring connectors
so
they can be removed and then reinstalled onto
the same station PCB later.
2.
Turn system power off.
I
January
1996
4-61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents