13.2 General Description
Remote
Administration
and
Maintenance
is
accomplished
with a remote
ASCII terminal/modem
communicating
over the public telephone
network via
either an external
modem
(connected
to a dedicated
CO line or a standard telephone
port) or a modem unit
(IMDU)
installed
on a PIOU or PIOUS
PCB or an
RMDS
installed
on a RSIU PCB-Release
3 and
above. See Figures 13-2 - 13-5.
Note:
Using
an
ASCII
terminal
for
Remote
Maintenance
(RM) is not recommended.
Toshiba recommends
that a 280Admin
PC be
used for RM.
Remote
Administration
and Maintenance
calls may
connect
to the IMDU
or RMDS
automatically
via
programmable
CO line ringing assignments
(Program
78) for ground/loop
start lines or via Program
*09
or
71-1 (l-3)
for DID/tie/DNIS
lines, or manually via the
standard call transfer feature at Directory Number #19.
Automatic
connection
allows remote
programming
to
be accomplished
after business
hours without on-site
assistance via night ringing assignments.
Remote
Administration
and Maintenance
allows the
following functions to be accomplished
remotely:
Program
Mode
provides for complete
programming
of
all Strata
DK280
programs
(including
Speed
Dial
adds/changes).
Test
Mode
provides
for testing
of Strata
DK280
stations and CO lines.
Data Dump Mode
provides a complete
printout of all
or individual
Strata
DK280
customer
database
programs,
including
Speed
Dial numbers
and LCD
messages.
Message
Mode
provides
for sending,
adding,
or
changing
digital
and electronic
telephone
LCD
messages.
Speed Dial Mode
allows Station and System Speed
Dial numbers to be programmed
remotely.
280Admin/280Backup
allows
program
download,
upload
and/or
editing
of DK280
system
programs,
System
Speed
Dial,
Personal
Speed
Dial,
LCD
messages,
voice mail codes and more. 280Admin
or
280Backup
requires a personal computer with Toshiba
280Admin
or 280Backup
software
and an operating
key connected
to the LPT2 port of the PC. This
section
of the DK280
I&M manual
does not provide
instructions
regarding
the
use of 280Admin
or
280Backup-refer
to the 280Admin
or the 280Backup
User Guides.
n
n
n
Program
Download
280Admin
and 28OBackup
allows the database
which is stored on a DK280
RCTU
PCB to be sent
to (and
stored
on) a
Personal
Computer
disk. To download
an RCTU
database
to a PC disk,
the
RCTU
must
be
operating
in a DK280 base cabinet;
and the PC
must have the Toshiba 280Admin
or 280 Backup
software
installed. Also, an RSIU, RSSU, PIOU or
PIOUS must be installed in any cabinet.
Program
Upload
280Admin
and 280Backup
allows the database
which is stored on a PC disk
to be sent to (and stored in) the RAM of an RCTU
PCB. To upload
an RCTU database
from a PC
disk,
the same
requirements
necessary
for
program download
are needed.
Edit of customer
database
can be accomplished
via 280Admin
PC software (not 280Backup)
on- or
off-line
with the DK280.
Refer to the 280Admin
User Guide for more information.
There
are two levels of Remote
Administration
and
Maintenance
protected
by a security code defined
in
Program 00.
Level 1
allows access to all programs.
Level
2 allows
access
to Programs
30 - 39 and
77 - 89, which
pertain
only to individual
station
options such as button assignments,
Class of Service,
etc.
Each Remote
Administration
and Maintenance
level
has a different
programmable
password
for customer
database
protection.
This allows a customer
to make
certain station moves, adds, and changes
in Level 2;
while protecting
the critical system
assignments
in
Level 1 (refer to Program 00).
13.3
Hardware
Requirements
The Strata DK280 must be configured
with either an
IMDU-equipped
PIOU or PIOUS, a RMDS-equipped
RSIU, or an external modem connected
to a dedicated
CO line or standard telephone
circuit. (A modem is not
required for local, on-site, maintenance.)