Program 1 O-3
-System
Assignments,
Part 3 of 3
SELECT
= 3 -J
L
Buttons/LEDs
Light LEDs as defined
by the table below.
ALL LEDs with an "X" should be lit when you finish.
-05
I I
042
PEKU Ports 33,34 - Amp. 4 Connected
Ports 33, 34 -
Stations Connected
03
PEKU Ports 25,26 - Amp. 3 Connected
Ports 25, 26 -
Stations Connected
02
PEKU Ports 17,18 - Amp. 2 Connected
Ports 17, 18 -
Stations Connected
01
PEKU Ports 09, IO - Amp. 1 Connected
Ports 09, 10 -
Stations Connected
Notes:
1.
initialized
data: LEDs
7 7 and 13 ON, a// other LEDs OFF.
2.
Amplifiers
are switched
into two-CO
line ca/ls automatically.
one amplifier
for each ca//. starting
from the
lowest ports
enabled
to the highest.
Skipping
ports is a//owed.
Two-CO
line calls established
after i
amplifiers
are in use will not be amplified.
RCTUB,
RCTUBAIBB,
and
Amplifiers,
RCTUA
allows
up to 3 Amplifiers.
all
I'"
set
,
"l-i-
1
ON
RCTUC/D
allows up to 4
240 set
t
ON
1 OFF
3.
The time the Auto Attendan;
will ring .&ations (per Program
81. 84, 87) after a loop start line caller does not dial and/or a ringing station does not
answer.
Set ring disconnect
time as shown
above.
If a call is not answered
before
ring disconnect
time period
time-out,
the call will disconnect.
This is to prevent
loop start lines from being locked-up
when there is no CPC supervision
from the central
office after the outside
caller hangs
"P.
4.
Set LED IO-13 ON so that their HEX values add up to the Voice Mail station
digit length for SMDI VM interface.
(Example:
For Vpf 00 or
Stratagy
SMDI interface,
set LEDs
IO, 11, and 12 on for 7 digits (1+2+4=7).
LEDs
lo- 13 should
be off for Toshiba
proprietary
VM interface.
5.
Toshiba
Proprietary
and SMDl is available
with RCTUB2
or RCTUCFtCTUD2
Release
2 and above on/y and is on/y for use with Toshiba
Vp
systems,
not with Toshiba
Stratagy
systems.
6.
When sending
Call /D/AN/
numbers
to voice mail via SMDI, LED s 08, 09, IO, 11, 12, 13, and 14 must be turned ON.
Genera/
Notes:
IMPORTANT
!
Only enable the PEKU and PESU ports that are actually
connected
to amplifiers.
Do not install T/E/D/D lines or the RATU PCB in slots with lower slot numbers
than amplified
conference
PEKtJ slots.
.
See Chapter
6-Peripheral
/nsta//ation
for COnrIeCting up to four two-way
amplifiers
for use on tandem,
DISA, External
Cal/ Fcward,
DN/S
external
routing,
and conference
telephone
calls.
.
See Program
10-2, LED 18 and 19; Program
1 O- 1, L EDs 19 and 20; and Program
15-5 for more information
regarding
Two-CO
line
conference/tandem.
lo-32
January
1996

Hide quick links: