Power Failure Options; Power Failure Emergency Transfer Option - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

This chapter
provides
connection
procedures
for
optional
peripheral
equipment
to Strata
DK280
systems.
The instructions
for each option
include
hardware
requirements,
printed
circuit board
(PCB)
configuration,
interconnection/wiring
requirements,
and programming
considerations.
Peripheral
equipment
is connected
to system PCBs.
Refer to PCB Installation,
Chapter
4-Printed
Circuit
Boards
for
PCB
installation
and
configuration
information.
6.1
Power Failure Options
Strata
DK280
systems
offer two options
to protect
system operation
in the event of a power failure: the
Reserve
Power
option
and
the
Power
Failure
Emergency
Transfer
option.
Reserve
power
installation
is described
in Chapter
3-Cabinet
Installation;
power
failure
transfer
installation
is
described below.
6.1 .l
Power
Failure
Emergency
Transfer
Option
The Power Failure Transfer
Unit (DPFT) provides
a
means
of automatically
connecting
up to eight
selected
CO lines directly
to designated
standard
telephones
in the event of a power failure. The DPFT
allows normal operation
of the selected CO lines and
standard
telephones
when the system
is in service.
When
power
is restored,
each
telephone
is
independently
reconnected
to the system
after that
telephone
is finished with its direct CO line call. The
DPFT is normally
installed
on the Main Distribution
Frame (MDF).
Figure 6-1 provides a circuit diagram of the DPFT.
Power Failure Emergency
Transfer
Installation
Install
the DPFT in accordance
with the following
steps:
1.
2.
3.
4.
5.
6.
7.
Mount the DPFT on or near the MDF.
Note:
Refer
to Chapter
7-Wiring
Diagrams,
DPFT/MDF
interconnecting
tables.
Using
25-pair
cables
with
amphenol-type
connectors
(female for DPFT connector
Jl, male
for DPFT connector
J2), connect the DPFT to two
66-type quick-connect
blocks.
Connect the CO lines selected for emergency
use
to the DPFT Jl-block
'CO-TIP"
and "CO-RING"
terminals.
Connect
the RCOU (or PCOU) circuits relateo to
the emergency
CO lines to the DPFT Jl-block
"RCOU-TIP"
and "RCOU-RING"
terminals.
Connect
the standard
telephone
stations selected
for emergency
use to the DPFT J2-block
"TEL-
TIP" and "TEL-RING"
terminals.
Connect
the
RSTU,
RDSU/RSTS
or PSTU
standard
telephone
circuits
related
to the
emergency
standard telephones
to DPFT J2-block
"PSTU/
RSTU-TI
P" and "PSTU/RSTU-RI
NG"
terminals.
Connect the DPFT to the RDSU/RSTU/PSTU
DG
and -24V terminals
(refer to Chapter
-/-Wiring
Diagrams
for RSTU/PSTU
and
RCOU/PCOU
wiring/interconnecting
details).
January
1996
6-l