Toshiba Strata DK 280 Installation Manual page 554

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Program 76-1
-
RSI U/RSIS/RMDS
Port Assignments
(R3)
I
PORT NUMBER 1 - 4 T
PORT TYPE: 0 = No port equipped'
--J
1 = TTY or modem2
2 = SMDR
3 = MIS
4 = SMDI
5 = OA (see Program 77-4)
(See Record Sheet below
for Program
76-1 data)
4
Program 76-2
-
RSIU/RSIS/RMDS
Port Assignments
(R3)
PORT NUMBER 1 * 4
T
TRANSMISSION
RATE: 1 9600 bps T
2 4800 bps
3 2400 bps
4 1200 bps
1 PROGRAM
1
76-1
1
76-2
I
I
PORT
PORT
I
DATA TRANSMISSION
NUMBER
TYPE'
RATE [bps]
I
I
3
I (0)
I
(3)
4
I(O)
(3)
( ) = Initialized Data
Total $9600
bps3
Notes:
1. Always enter port type code '0" for non-equipped
ports.
2. If port type code 1 is set, then Program 77- 1, LED 14 status determines if the port operates as a system
administration/maintenance
modem (LED 14 ON) or an RS-232 administration/maintenance
TTYport (LED 14
OFF). For modem operation, a RMDS piggy-back
PCB is required, for RS-232 TTYport, an RSIU/RSIS or
RMDS PCB may be used.
3. The transmission
data rate sum of the equipped RSIU/RSISI/RMDS
port can not exceed 9600 bps.
4. System power must be cycled or Program 91-2 must be run to transfer Program 76-1 data entries from
temporary memory to working memory; Program 76-2 does not require data transfer.
General Note:
l
Initialized Data = (), codes set in Program 76 have priority over codes 4 I, 42, and 43 set in Program 03 for
PIou/PIous
ports.
IMPORTANT
!
Whenever uploading Program 76 with 280Admin/280Backup,
the bps rate of 28OBackup/28OAdmin,
the customer
database (on the PC) and the RSIlJ/RSIS/RMDS
TTVRMDS
port must all be set the same. If the bps rate of
these items are not the same, uploading Program 76 will fail.
DK0388
1 O-l 40
February
1996