Toshiba Strata DK 280 Installation Manual page 427

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Program 03 -
Flexible
PCB Cabinet
and Slot Assignments
(continued)
Notes:
1.
The RCTUA, RCTUB, RCTUBB or RCTUD PCB must be installed into the RCTU slot in cabinet 1. Enter slot
00 to assign PCB code 91 - 94 to RCTUA or RCTUB installed in RCTU slot; enter slot 01 to assign code 91
- 94 to RCTUD installed in the RCTU slot. The RCTUBA or the RCTUC PCB must be installed in slot R7 7 in
cabinet 1, enter slot number 00 to assign a PCB code 91 - 94 to the RCTUBA or RCTUC PCB installed in the
RI 1 slot.
IMPORTANT!
RCTUBB code should always be set as follows: Slot 01=91.
2.
A.
If an RSIU PCB is not installed in slot 1 I, the programming
station (205 - Port 005) must be connected
to
circuit 6 in slot Il. The station must be a 20-button
digital or electronic telephone
with an LCD. A PDKU
or PEKU should be installed in slot 11, if RSlU is not installed (see Note 28).
B. If RSILJ is installed in slot 17, the programming
station (005) must be connected
to circuit 6 in slot 12.
A
PDKU or PEKU should be installed in slot 12 (R3); in this case, Station Port Number 000 - 007 will be in
slot 12.
3.
Do not install PCBs in slots 527, S28, S37, and S38, they are for future use.
4.
Code 47,42,
and 43 assigns PIOU/P/OUS
RSSU m/port
as Remote Maintenance,
MIS for ACD, and SMDI
respectively;
SMDR, Paging, Relay Control, and other miscellaneous
options will be active on the PlOU or
PIOUS that has the lowest number code (41, 42 or 43) in the system. Codes set for RSIU/RSlS/RMDS
in
Program 76 have priority over codes 4 1, 42, and 43.
5.
Install RATU and all tie/DID line PCBs in higher numbered
slots than station PCB slots whenever practical so
station port numbers remain in numerical order (see Chapter
I-Configuration,
Worksheet 2).
6.
Do not install PCBs in slots 547, S48, S57, 558, 567, and S68, they are for future use.
7.
Program 91- 1 and 91-9 will automatically
assign PCB codes (marked by footnote "9") if the appropriate
Host
PCB is installed
when Program
91- 1 or 91-9 is run; Programs
9 l- 1 or 91-9 do not assign option codes;
Program 03 must be run to assign codes for all options except RCOS (codes not marked with "9"). Program
91-9 will erase option codes assigned
with Program 03, Program 91- 1 does not erase option codes already
programmed.
After completing
all Program 03 data entry, run Program 91-2 (R3 and above) or cycle system
power to transfer Program 03 data info working memory.
\
CAUTION !
Program 91-2 will simulate turning the system power OFF/ON and will drop all calls in progress.
8.
When using RCTUA, Slot 15 and 16 does not support OCA or DIU.
9.
ACD, ACD/MIS,
RS-232 Voice Mail Integration
(SMDI or Toshiba Proprietary),
and attendant
console is
for use with Release 2 and above only. RCTUA does not suppot? these features.
10. RSIU must be installed in universal slot II of the base cabinet (R3). (See Note 2 above.)
11. RCIU/RCIS
circuit numbers will be assigned automatically
in numerical order (001 - 144) starting with the
lowest RCIU/RCIS
slot number,
to the highest RCIU/RCIS
slot number
in 8-circuit increments.
Never
install
RCILJ without
RCIS if more
than 4 circuits
are needed.
RCIU/RCIS
can be installed in any
universal slot except slot 1 I; they do not have to be installed adjacent to corresponding
CO lines. Refer
to Program
* 5 0 to manually assign RCIU/RCIS
circuits to CO line circuits (R3).
General Notes:
l
See Table 8-7 in Chapter
8-Programming
Introduction
and notes on this page for more details when
entering Program 03 Data.
l
System power must always be cycled or Program 91-2 must be run after running Piogram 03 to transfer data
from temporary
memory to working memory.
.
Program 03 should be run when adding PCBs to an existing system.
January 1996
10-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents