Toshiba Strata DK 280 Installation Manual page 395

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

2.
The TTY and Modem
function
cannot
operate
on separate
RSIU/RSIS/RMDS/
RSSU/PIOU/PIOLJS
ports simultaneously;
if both functions
are programmed
at the
same time on separate ports, the function
of the lowest
numbered
RSIWRSIW
RMDS port (TTY or Modem) will be active.
3.
System power
must be turned off/on
or
Program
91-2 must be run to transfer
Program
76- 1 anytime
Program
76-1 is
changed.
4.
If code Y=l is set to enable
the RSIU,
RSIS or RMDS to function as a TTY RS-
232 maintenance
port, turn Program 77- 1,
LED 14 off. To enable the RMDS remote
modem operation,
Program
77-l LED 74
must be ON.
Program
76-2(X-Z)-RSIU/RSIS/RMDS
Port
Assignments
Assigns
each installed
RSIU port to operate
at a
specified
transmission
rate. Where
X identifies
the
RSIU/RSIS/RMDS
Port No.1 - 4 and Z identifies the
RSIU/RSIS/RMDS
port transmission
rate in bits-per-
second (bps) as shown below.
H
Z=l ,960O bps
n
Z=2,4800
bps
4
Z=3,2400
bps
q
Z=4,1200
bps
Note:
The sum
of the
transmission
rates
of
equipped
RSIWRSISIRMDS
ports
cannot
exceed 9600bps.
Ports assigned
"no-function"
(code
0) in Program
76-2X-Y
will not be
included
in the transmission
rate sum. The
RMDS will only function at 1200 or 2400 bps
(see Program 77- 1 LED15).
Program
77-1 -Peripheral
Options
(Initialized data reads all LEDs OFF.)
n
Door Lock Time, LED 20-The
Door Lock Relay
contact may be programmed
to operate for either
three or six seconds
(applies
to PIOU, PIOUS,
PEPU, DDCB, and HDCB door lock controls).
n
Port Number/Door
Phone/Lock
Control
Units,
LEDs 16 - 19-Door
phone/lock
existence
is
defined
by this
program.
Door
phone/lock
controllers (DDCBs and/or HDCBs) can only exist
at Ports 004, 012, 020 and 028, and can only be
installed
on Circuit 5 of a PDKU, RDSU,
PEKU
and/or
PESU.
PDKUs
and
RDSUs
support
DDCBs, but not HDCBs. PEKUs and PESUs can
support HDCBs, but not DDCBs. After assignment
of a DDCB or HDCB, door phone numbers (#151
- #159, #161 - #163) will effectively
replace the
station
number
assignment
in Program
04. The
door lock option is set via Program 77-2.
n
RMDS or IMDU Modem,
LED 14-This
program
enables
the DK280 built-in maintenance
modem
function:
RMDS or IMDU. If the RMDS or IMDU
remote modem is used, turn "On" LED 14, if the
RMDS or IMDU is not used, turn "Off" LED 14.
Only one DK280 built-in modem RMDS or IMDU
can be used in the DK280; if both are installed,
RMDS will be accessed
when a CO line direct
rings the modem or is transferred
to the modem
by dialing Cnf/Tm+M9.
If LED 14 is off, the RSIU Port (l-4)
which is set
for TTY operation
(Code 1 in Program
76-l) will
operate
as a local RS-232 maintenance
port. If
RSIU
is not configured
as TTY,
then
the
PIOU/PIOUS/RSSU
that has code
41 set in
Program
03,
will
operate
as a local
TTY
maintenance
port.
Other system Programs
that are related
to the
system
modem
are: Program
76, RMDSJTTY
assignments
on RSIU PCB; Program
78-51-53,
system CO line to modem ringing assignments;
Program
71-1,
DNIS
line to modem
ringing
assignments:
Program
*09, DID line to modem
ringing
assignments:
Program
77-1,
LED 15,
RMDS modem Protocol/speed
assignments.
W RMDS Protocol,
LED 15-This
program sets the
RMDS
communications
standard
type
to
CCIlTN.22bis
(2400bps)
or Bell 212A (1200bps).
The standard
set in this program
must match the
standard
of the modem
that
will be used
to
communicate
with the DK280 RMDS.
If the
RMDS
modem
standard
should
be
2400bps/CCITT/
V.22bis,
turn LED 15 on; if the
RMDS standard is a 1200 bps/Bell 212A, turn LED
15 off. Most
Hayes
compatible
modems
will
function
with either
standard;
check
with the
modem
manufacturer's
documentation
to verify
which protocol should be used. When the system
is initialized the Bell 212A (1200 bps) standard
is
set (LED 15 off).
January
1996
9-35