Ddcb And Hdcb/Drlk Assignments Guide - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Note:
Only one door lock control is available
using
an option
interface
PCB (PIOU, PIOUS,
or
PEPU). Only the PIOU, PIOUS, or PEPU with
the lowest Program
03 Code (41, 42, or 43)
will provide the door lock function.
1.
Access
Program
77-i.
Set LED 07 to ON to
configure
the DET/DER
for the door lock control
function.
2.
Access Program 77-l.. Set LED 20 to OFF for a 3-
second door lock activation time, or set LED 20 to
ON for a 6-second door lock activation time.
3.
If using a PIOU or PEPU, set the PI0 jumper plug
on the PIOU or PEPU to the MAKE or BREAK
position, as required:
n
MAKE-Shorts
the normally
open contacts
(pins 7 and 32) when
a station's
door lock
button is pressed.
n
BREAK-Opens
the normally closed contacts
(pins 7 and 32)
h
w en a station's
door lock
button is pressed.
- or -
If using a PIOUS, solder the Wl jumper
plug on
the PIOUS to the MAKE or BREAK position,
as
required:
n
MAKE-Shorts
the normally
open contacts
(DET and DER) when a station's
door lock
button is pressed.
n
BREAK-Opens
the normally closed contacts
(DET and DER) when a station's
door lock
button is pressed.
4.
Refer
to Figure
6-9 for wiring/interconnecting
details.
Connect
the PIOU, PIOUS,
or PEPU to
the MDF as required
for the door lock control
function.
Door lock Control
with
DDCB and HDCB
In addition to the option interface PCB (PIOU, PIOUS,
PEPU),
each digital
door
phone/lock
control
unit
(DDCB)
and electronic
door phone/lock
control
unit
.(HDCB)
can provide
one door
lock control.
This
capability enables as many as four DDCB/HDCB
door
lock
controls
to be provided
with
RCTUB
and
RCTUC/D,
or three with RCTUA. DDCBs connect only
to digital
circuits
(always
Circuit
5 on a PDKU or
RDSU) associated
with ports 004, 012, 020, and 028;
HDCBs
connect
only to electronic
circuits
(always
circuit 5 on a PEKU or PESU) associated
with ports
004, 012,020,
and 028.
It is important
to note that each DDCB/HDCB
door
lock control
reduces
the maximum
door
phone
capacity
by one. Configure
each DDCB/HDCB
for the
door lock control function as follows:
DDCB
Installation
See figure 6-10 and Chapter
7-Wiring
Diagrams-
DDCB Wiring Diagram and follow these steps:
1.
Connect
PDKU circuit 5 (T/R and PT/PR) to the
DDCB HKSU modular jack.
2.
Connect
the door lock wire pair to the DDCB
modular B-jack (pins 3 and 4).
3.
On the DDCB, set SW1 to the DOOR position.
4.
On the DDCB, set SW2 to the LOCK position.
5.
SW3 inside the DDCB can be set to open or close
the door lock relay whenever
a door lock button is
pressed:
if SW3 is in the "l-2" position, the relay
will provide a closure when the button is pressed;
if in the "2-3" position, the door lock relay will open
when the door lock button is pressed.
Note:
S W3 comes
from
the factory
in the "l-2"
position.
6.
In Program 77-1, set the door lock activation
for
three
or six seconds
and enable
the PDKU or
RDSU ports for DDCB connection.
7.
In Program 77-2, enable the DDCB B-jack for door
lock operation.
8.
In Program
39, assign
door
lock buttons
to
stations per the customer's
record sheet.
9.
Check each telephone
door lock button from each
station: the DDCB modular
B-jack (pins 3 and 4)
will momentarily
open
or close
(three
or six
seconds) when the button is pressed.
Note:
The DDCB SW4 strap is not used with Strata
DK280 systems.
The strap provides
an alarm
function with other Strata sys terns.
.
I
6-12
January
1996