REP 5.10 Set Gate Solenoid Assembly
Parts List on
PL 20.5
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Open DADF Top Cover.
2.
Remove the DADF Front Cover
(PL
3.
Remove the Entrance Tray
(PL
20.1).
4.
Remove Lower Chute Assembly
(REP
5.
Remove Set Gate Solenoid Assembly
1
Make note of pin
engagement
2
Disconnect
3
Release clamp
and remove wire
Figure 1 Removing Set Gate Solenoid Assembly
Repairs and Adjustments
REP 5.10
WARNING
20.1).
5.8).
(Figure
1).
4
Loosen screws
(2) and remove
solenoid
Replacement
1.
Engage pin with slot
(Figure
2).
Figure 2 Engaging Pin with Slot
09/03
4-30
Slot
Pin
Initial issue