RealPresence Collaboration Server (RMX) 800s/Virtual Edition Administrator's Guide
RealPresence Collaboration Server 800s - Default IP Network Service – Security (SIP Digest)
Field
SIP Authentication
User Name
Password
H.323 Authentication
User Name
Password
If the Authentication User Name and Authentication Password fields are left empty, the SIP Digest
authentication request is rejected. For registration without authentication, the Collaboration Server
must be registered as a trusted entity on the SIP server.
Polycom®, Inc.
Description
Click this check box to enable SIP proxy
authentication.
Select this check box only if the authentication is
enabled on the SIP proxy, to enable the Collaboration
Server to register with the SIP proxy. If the
authentication is enabled on the SIP proxy and
disabled on the RMX, calls will fail to connect to the
conferences.
Leave this check box cleared if the authentication
option is disabled on the SIP proxy.
Enter the user name the Collaboration Server will use
to authenticate itself with the SIP proxy. This name
must be defined in the SIP Proxy.
Enter the password the Collaboration Server will use
to authenticate itself with the SIP proxy. This
password must be defined in the SIP proxy.
Click this check box to enable H.323 server
authentication.
Select this check box only if the authentication is
enabled on the gatekeeper, to enable the
Collaboration Server to register with the gatekeeper. If
the authentication is enabled on the gatekeeper and
disabled on the RMX, calls will fail to connect to the
conferences.
Leave this check box cleared if the authentication
option is disabled on the gatekeeper.
Enter the user name the Collaboration Server will use
to authenticate itself with the gatekeeper. This name
must be defined in the gatekeeper.
Enter the password the Collaboration Server will use
to authenticate itself with the gatekeeper. This
password must be defined in the gatekeeper.
These fields can
contain up to 20 ASCII
characters.
These fields can
contain up to 64 ASCII
characters.