MERLIN LEGEND Communications System Release 5.0
Installation 555-650-140
Prior Releases Features and Enhancements
Release 4.0 Enhancements
— Forward Disconnect. All ports on 012 and 016 modules now
7-digit password for SPM
Release 4.0 has increased system security by requiring a 7-digit
password when using SPM to perform remove administration or when
performing the Trunk Test procedure. This password is to be used in
addition to the Remote Access barrier codes.
send forward disconnect to all devices connected to them when
forward disconnect is received from the CO. This enhancement
prevents the trunk/line from being kept active when one end
disconnects from the call. If an answering machine is connected
to the port, it will not record silence, or busy tones, or other
useless messages. This is a non-administrable operation.