Installation 555-650-140
Initializing and Testing the System
Testing the System
Testing Two-Way Dial-Repeating Tie Trunks
For two-way dial-repeating tie trunks, perform both the incoming and outgoing
dial-repeating tie trunk tests.
Testing Incoming Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or incoming only.
If you are testing two-way dial-repeating tie trunks, perform the outgoing test as
well.
To test incoming dial-repeating tie trunks, follow the steps below:
Have the person at the far end place a dial-repeating call to your


telephone by dialing the proper tie-trunk number.
Your telephone rings and the green LED next to ICOM (or SA for
Hybrid/PBX systems) flashes.
Pick up the handset.


The red LED next to the ringing button turns on and the green LED
changes from flashing to steady.
Verify that you have good two-way communication and hang up.


The green LED should turn off, the red LED should turn off, and another
red LED may turn on.
Repeat Steps 1 through 3 for each incoming or two-way


dial-repeating tie trunk.
Testing Outgoing Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or outgoing only.
If you are testing dial-repeating two-way tie trunks, perform the incoming test as
well.
To test outgoing dial-repeating tie trunks, follow the steps below:
At any telephone that has access to a dial-repeating tie trunk, press


the first tie-trunk button.
The red LED next to the pressed tie-trunk button lights.