MERLIN LEGEND Communications System Release 5.0
Installation 555-650-140
Connecting Data Equipment
Video Conferencing Data Stations
c. Use the DB-37 cables to connect the EIA-232/V.35 converters to
If it is not already connected, connect the CSU to the 100D module


on the control unit and to the 5ESS or 4ESS exchange switch.
See
''Installing the Channel Service Unit''
When you are ready to power up the system, plug the power


supplies, CSU, video conferencing equipment, and control unit into
the AC outlets.

Terminal Adapter and CSU Settings

You need to set the terminal adapter and the CSU as indicated in
the customer's system is running at 56 kbps, set the CSU line-coding DIP
switches according to the instructions in "Setting the CSU DIP Switches" in
Chapter
4.
Table 6-2.
Terminal Adapter Settings
Settings
Auto-dial
Busy out
Datarest
DTR
Duplex
Mode
Speed
the video codec's V.35 communication ports. See the
documentation packaged with the video codec for instructions.
56 Kbps
Off
Off
On
Follow
Full
Cs
56,000
in
Chapter
4.
64 Kbps
Off
Off
Off
Follow
Full
Cs
64,000
Issue 1
June 1997
Page 6-21
Table
6-2. If

Advertisement

Table of Contents
loading
Need help?

Need help?