MERLIN LEGEND Communications System Release 5.0
Installation 555-650-140
Installing the Control Unit
Installing the Modules
Installing Modules
To install modules starting from slot 1 (the first open slot next to the processor),
follow the steps below:
For each 400EM tie line/trunk module, for jacks numbered 1 through
4 in
Figure
signaling type.
Set the dual in-line packaging (DIP) switches on the front of the 400EM
Tie Trunk module according to the E&M signaling type settings listed in
Table 2-4
nal does not require any adjustments in the DIP switches.
Remove the protective cover from each module's gold-finger
connector.
Lower the hook on top of the module onto the rod on the top of the
carrier in the appropriate slot. See
Make sure the connector on the module mates properly with the
connector on the carrier.
Swing the module into the slot and firmly push the module into the
carrier until it locks into place.
!
CAUTION:
To avoid damage, do not force the module. If the module does not
insert easily, press the bottom rear locking tab, remove the module,
and inspect the module and carrier for damage or obstruction.
If there is no damage and no obstruction, reinsert the module. A
damaged carrier or module must be replaced.
Repeat Steps 1 through 5 for each module you want to install.
2-11, check Form 3c, Incoming Trunks: Tie, for E&M
and
Table 2-5
and shown in
Figure
2-11. The default E&M sig-
Figure
2-10.
Issue 1
June 1997
Page 2-34
Need help?
Do you have a question about the MERLIN LEGEND Release 5.0 and is the answer not in the manual?