Connecting A Cat To The Control Unit; Connecting A Printer To The Control Unit - Lucent Technologies MERLIN LEGEND Release 5.0 Installation Manual

Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
Installation 555-650-140
Installing the PC, CAT, or Printer

Connecting a CAT to the Control Unit

Connecting a CAT
to the Control Unit
The Call Accounting Terminal (CAT) is a stand-alone unit that provides call
accounting information. It connects to the SMDR jack on the control unit and
links the control unit to the CAT printer. The connection of the CAT to the control
unit depends on the distance and whether the CAT and control unit share the
same AC outlet.
The CAT and CAT printer are connected at the same time. For more
information, see
If the CAT is grounded to the same AC outlet as the control unit and the
CAT and CAT printer are within 14 ft. (4.27 m) and 50 ft. (15.2 m),
respectively, of the control unit, refer to
on the Same AC
If the CAT is either not grounded to the same AC outlet as the control unit
or is more than 14 ft. (4.27 m) from the control unit, refer to
a CAT and Printer on a Different AC
!
CAUTION:
To prevent damage from electrostatic discharge (ESD), avoid touching
leads, connectors, pins, and other components. Wear a properly
grounded wrist strap.
Connecting a Printer
to the Control Unit
You can connect any 1200-bpi serial printer set at no parity and one stop bit. If
necessary, consult the printer's manual to ensure that these settings are in
effect. The system supports the following Lucent Technologies printers:
Lucent Technologies 572 Printer
Lucent Technologies 475/476 Printer
''Call Accounting Terminal''
Outlet''.
in
Chapter
8.
''Connecting a CAT and Printer
Outlet''.
Issue 1
June 1997
Page 5-7
''Connecting