MERLIN LEGEND Communications System Release 5.0
Installation 555-650-140
Connecting Data Equipment
MLX Voice and Terminal Adapter Data Stations
MLX Voice and Terminal Adapter
Data Stations
Figure 6-4
shows the equipment configuration for MLX voice and terminal
adapter data station.
The configuration shown in
data transmission. For information on setting up synchronous terminal adapter
data stations, see
The maximum cord length from the terminal adapter to the telephone is 80 ft.
(24.38 m).
Setting Up
To set up an MLX voice and terminal adapter data station, follow the steps
below:
Use an EIA-232-D cable to connect the serial port on the data
terminal to the terminal adapter.
If the data terminal that has both COM1 and COM2 connectors, make
sure you use the one designated for data transmission. See the
customer's system manager if you are not sure.
Make sure the terminal adapter option settings for parity and speed
are compatible with the data terminal. (Speed is synchronized
automatically if the factory setting has not changed.)
If you are not sure about the speed and parity of the data terminal, see
the customer's system manager or the documentation packaged with the
terminal adapter and data terminal.
Plug the other end of the EIA-232-D cable into PORT 1 on the
terminal adapter.
Plug the WP90110-L7 power supply cord into the POWER
receptacle on the terminal adapter.
Figure 6-4
''Video Conferencing Data Stations''
is for asynchronous terminal adapter
later in this chapter.
Issue 1
June 1997
Page 6-12