Unit Load Calculation Worksheet
Unit Load Worksheet
5. Calculate the estimated unit loads.
Module
008
008 MLX
008 OPT
012
016
100D
400
400 EM
400 GS/LS/TTR
408
408 GS/LS
408 GS/LS-MLX
800
800 NI-BRI
800 GS/LS
800 GS/LS-ID
800 DID
MERLIN LEGEND
Mail
If the total is less than or equal to 54, any power supply module is
sufficient.
If the total is greater than 54, continue to Step 6.
Qty
x
Unit Load
Total Estimated Unit Load
= Total
12.0
13.5
8.0
8.4
12.8
0.0
0.0
8.0
8.0
12.0
12.0
13.5
0.0
0.0
0.0
8.0
8.0
0.0
Issue 1