Installing the Control Unit

Installing the Modules

Installing the Modules
!
CAUTION:
When installing the modules, use a properly grounded wrist strap to
prevent damage from electrostatic discharge (ESD) , and avoid touching
leads, connectors pins, and other components.

Guidelines

Follow these guidelines when you install modules, as indicated on the Control
Unit Diagram of Form 1, System Planning:
Do not leave empty slots between modules. The system ignores
modules installed beyond any empty slot.
If a phantom module (a programmed empty slot) is indicated on the
Control Unit Diagram, make sure the slot remains empty and do not
install any modules to the right of it. The system ignores any modules
installed to the right of a programmed empty slot.
Make sure you install each module in its assigned slot. If you install a
module in the wrong slot, the system will not function properly.
Be sure to place all 012 modules and all 008 OPT modules without
built-in ring generators in carriers with modules that have ring generators
so that the modules without ring generators can be supported.
NOTE:
All 016 modules and some 012 modules (apparatus code 517G13
or later) have built-in ring generators.
Once you have installed the power supply and the processor in the basic
carrier, use the remaining slots for the modules as follows:
— Basic carrier: slots 1 through 5
— First expansion carrier: slots 6 through 11
— Second expansion carrier: slots 12 through 17
Issue 1
June 1997
Page 2-33