Create Cfm Ma - D-Link DGS-3000 Series Reference Manual

Layer 2 managed gigabit switch
Hide thumbs Also See for DGS-3000 Series:
Table of Contents

Advertisement

DGS-3000 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
Parameters
<string 22> - Enter the maintenance domain name. This name can be up to 22 characters long.
md_index - Specifies the maintenance domain index.
<uint 1-4294967295> - Enter the maintenance domain index value here. This value must be
between 1 and 4294967295.
mip - (Optional) Specifies to configure MIPs.
none - Specifies not to create MIPs. This is the default value.
auto - MIPs can always be created on any ports in this MD, if that port is not configured with
an MEP of this MD. For the intermediate switch in an MA, the setting must be automatic in
order for the MIPs to be created on this device.
explicit - MIPs can be created on any ports in this MD, only if the next existent lower level has
an MEP configured on that port, and that port is not configured with an MEP of this MD.
sender_id - (Optional) Specifies the control transmission of the sender ID TLV.
none - Specifies not to transmit the sender ID TLV. This is the default value.
chassis - Transmits the sender ID TLV with the chassis ID information.
manage - Transmits the sender ID TLV with the managed address information.
chassis_manage - Transmits sender ID TLV with chassis ID information and manage
address information.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure the maintenance domain called "op_domain" and specify the explicit option for
creating MIPs:
DGS-3000-26TC:admin#config cfm md op_domain mip explicit
Command: config cfm md op_domain mip explicit
Success.
DGS-3000-26TC:admin#
16-3

create cfm ma

Description
This command is used to create a maintenance association. Different MAs in an MD must have
different MA Names. Different MAs in different MDs may have the same MA Name.
Format
create cfm ma <string 22> {ma_index <uint 1-4294967295>} md [<string 22> | md_index
<uint 1-4294967295>]
Parameters
<string 22> - Enter the maintenance association name. This name can be up to 22 characters
long.
ma_index - (Optional) Specifies the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value must
be between 1 and 4294967295.
150

Advertisement

Table of Contents
loading